  1.                   MICROPOLIS 1598 DISK DRIVE 
  2.                         SPECIFICATIONS 
  3.  
  4.                                        Model Number 
  5. Unformatted Capacity:                   1598-15 
  6.  
  7.   Total Mbytes            --------------- 1203.0 ----------------
  8.   Disk Platters           ------------------- 8 ----------------- 
  9.   Read/Write Heads        ------------------ 15 -----------------
  10.   Cylinders               ---------------  1928 -----------------
  11.   Bytes per track         -------------- 41,664 -----------------
  12.  
  13. Formatted Capacity 
  14.  
  15.   Total Mbytes            --------------- 1034.6 ----------------
  16.   Bytes per Sector        ----------------- 512 -----------------
  17.   Sectors per Track       -----------------  71 -----------------
  18.  
  19. PC Setup 
  20.  
  21.   When using SCSI in a PC, the most common method is to run your 
  22.   setup program and define No Drives Present. The SCSI Host Adapter
  23.   will automatically self-configure on power-up. To install the  
  24.   drive, follow the manufacturer's instructions to use the on-board
  25.   BIOS routine or software that was supplied with the Host Adapter.
  26.  
  27. Performance Specifications 
  28.  
  29.   Seek Time                       Track-to-Track           4 msec 
  30.     (including settling time)     Average               14.5 msec
  31.                                   One-third Stroke(max) 15.5 msec
  32.                                   Maximum                 33 msec
  33.   Average Rotational Latency                            8.33 msec
  34.  
  35.   Rotational Speed                              3600 rpm +/- 0.5%
  36.  
  37.   Data Transfer Rate at Interface 
  38.     Synchronous                                    4.0 Mbytes/sec
  39.     Asynchronous                                   1.8 Mbytes/sec
  40.  
  41.   Internal Data Rate                                 20 Mbits/sec
  42.  
  43.   MTBF                                              150,000 hours
  44.  
  45.   Positioner                     Fully balanced rotary voice coil
  46.  
  47.   Parking                                 Automatic park and lock
  48.  
  49.  
  50. General Functional Specifications 
  51.  
  52.   Interface                                                SCSI-2
  53.  
  54.   Supports Common Command Set                                 YES 
  55.   Write Precompensation Start Cylinder                       1928 
  56.   Reduced Write Current Start Cylinder                       1928
  57.   Landing Zone                                               1928
  58.   Mounting Plane                                  Any orientation
  59.  
  60. Power Requirements 
  61.  
  62.   +12V +/-5%                                            2.0 A Avg
  63.                                       (4.35A max during start-up)
  64.   +5V +/-5%                                              2.0A avg
  65.   Power dissipation, typical                             30 Watts
  66.  
  67.  
  68. 7. Drive Addressing and Interface Termination 
  69.  
  70.  
  71.               _ID2 
  72.              |  _ID1 
  73.              | |  _ID0 
  74.              | | |                        Pin 1 
  75.          J2  | | |              J1            |       J3  
  76.       ___________    __________________________     ________ 
  77.     _|           |  |                          |   |        | 
  78.    | |___________|_ |__________________________|___|________| 
  79.    |  ..  ..                                                | 
  80.    |  W5  W4          RN9         W2                        | 
  81.    |                              W1                 W11    | 
  82.    |                                                        | 
  83.    |                                                    W28 | 
  84.    |                                                        | 
  85.    |                                                        | 
  86.    |                                                        | 
  87.    |                                                        | 
  88.    |                                                        | 
  89.    |                                 Component Side         | 
  90.    |                                                        | 
  91.  
  92.  
  93. ID0, ID1, ID2 SCSI Address Jumpers 
  94.   The SCSI ID (drive address) jumpers are identified as ID0, ID1,
  95.   and ID2. ID selection is binary, as shown in the table below. 
  96.  
  97.    SCSI              Jumpers 
  98.   Address        ID2   ID1   ID0 
  99.   -------        ---   ---   --- 
  100.      0           out   out   out 
  101.      1           out   out    in 
  102.      2           out    in   out 
  103.      3           out    in    in 
  104.      4            in   out   out 
  105.      5            in   out    in 
  106.      6            in    in   out 
  107.      7            in    in    in 
  108.  
  109.   For multiple drive installations, on one Host Adapter, each drive
  110.   must have a unique address. Drives are configured as SCSI ID 7
  111.   at the factory. 
  112.  
  113. RN9 Interface Terminator 
  114.   The Interface Terminator factory installed at RN9 provides    
  115.   proper termination for the interface lines. When daisy-chaining 
  116.   multiple drives, leave the terminator installed only in the last
  117.   physical drive (or drives) on the daisy chain cable; remove the
  118.   terminator from each of the other drives (or the host computer).
  119.  
  120. W1, W2, Terminator Option 
  121.   W1 and W2 select the source of terminator power (+5V) for the  
  122.   interface terminator. If a jumper is installed at W1(the factory
  123.   default configuration), and no jumper is installed at W2 the  
  124.   drive provides terminator power. This configuration is used    
  125.   for PC/AT applications. If a jumper is on W2 the host adapter  
  126.   will supply terminator power. If a jumper is installed at W2 and 
  127.   W11, and no jumper is installed at W1 the drive provides       
  128.   terminator power to it's on-board terminators and also to the  
  129.   SCSI bus via interface connector J1, pin 26. 
  130.  
  131. W11 Bus Option 
  132.   W11 allows the drive to supply interface terminator power to the
  133.   SCSI Bus. If W11 is not installed and W1 is jumpered (the factory
  134.   default configuration), the drive does supply SCSI bus interface 
  135.   terminator power. W11 should not be installed for PC/AT        
  136.   applications. 
  137.  
  138. W5 Spindle Option 
  139.   Selects the spindle control option. If W5 is jumpered, the    
  140.   drive must wait for a Start Spindle command (after power is    
  141.   applied) to start the spindle motor. If W5 is not installed    
  142.   (the factory default configuration), the drive automatically   
  143.   starts the spindle motor at power-on. W5 is not installed for 
  144.   PC/AT installations. 
  145.  
  146. W4 Bus Parity Option 
  147.   W4 selects the parity check option. If W4 is installed, the drive
  148.   neither generates nor detects parity. If W4 is not installed (the
  149.   factory default configuration), the drive generates parity and
  150.   enables parity detection. W4 is usually not installed for PC/AT
  151.   applications. Verify the correct configuration required by your
  152.   Host Adapter. 
  153.  
  154. W28 Ground Options 
  155.   W28(only implemented on Rev B and later boards) is used to     
  156.   connect the drive's logic ground to frame ground. When at jumper
  157.   is installed at W28, frame ground is connected to logic ground.
  158.  
  159.   When a jumper is not installed at W28 (the factory default   
  160.   configuration), frame ground is not connected to logic ground.